Guidance / The lead

Radically
responsive.

A new level of control and shape retention in tortuous neurovascular anatomy. At its core is the polymer-metal matrix: the core wire is centered and fixed within the coil, forming one integrated structure.

Rx Only
WaveSelect 1014
0.010inDistal OD
0.014inProximal OD
200cmTotal length
46%Less tip stiffness*
Polymer-metal matrix

No gap between coil and core.

A flexible polymer fill eliminates the gap between the coil and the core wire, integrating the components for new combinations of performance in a smaller profile.

Cross-section of the WaveSelect polymer-metal matrix compared with a conventional wire
Shape

Exceptional tip shape retention.

Reduces the relaxation and deformation seen with conventional wires after multiple passes through tortuous anatomy. Bench testing shows the tip holds its shape after simulated multiple vessel passes.

Torque

Enhanced torque transmission.

The polymer fill carries torque from the proximal core through the matrix to the tip. A cylindrical, tapered tip avoids restricted two-dimensional movement.

46%

Less tip stiffness.*

The straight version has 46% less tip stiffness than conventional wires such as Synchro 14, for navigation in complex procedures.

Support

A supportive mid-shaft.

Rail for 0.013 in tip microcatheter delivery at conventional wire levels, demonstrated in the distal 15 cm.

*Bench testing. May not be indicative of clinical performance.

"Prior to WaveSelect I likely would have used multiple competitive wires for this tortuous vessels case, but I only had to use a single WaveSelect due to its impressive shape retention."

Dr. Timo Krings, Lahey Hospital & Medical Center, MA
WaveSelect shaped tip
Specifications

GW1410 at a glance.

SpecificationValue
Product codeGW1410
Distal OD0.010 in
Proximal OD0.014 in
Total length200 cm
Radiopaque tip length3 cm
Coil length30 cm
TipStraight, shapeable
CoatingPTFE
Compatibility0.013 in tip microcatheters
Where it fits

The lead for SurfRider 13.

WaveSelect 1014 guides SurfRider 13 into distal targets and facilitates delivery of embolic devices.

Indications for use

The WaveSelect Wire is intended for use in guiding microcatheters to the neurovasculature. WaveSelect facilitates the delivery of embolic devices for the endovascular treatment of brain aneurysms and other neurovascular conditions.

Important Safety Information
Evidence

WaveSelect in U.S. labs.

All cases

Case results may not be indicative of results in other cases.

Request an evaluation

See WaveSelect 1014 in your own cases.

Your territory representative will set up product, in-service and case support for your lab.

Rx Only
Prototype form. Submissions are not sent.

Thank you. Your request is in.

Your Kaneka Neurovascular representative for your territory will reach out within one business day.