Radically
responsive.
A new level of control and shape retention in tortuous neurovascular anatomy. At its core is the polymer-metal matrix: the core wire is centered and fixed within the coil, forming one integrated structure.
Rx Only
No gap between coil and core.
A flexible polymer fill eliminates the gap between the coil and the core wire, integrating the components for new combinations of performance in a smaller profile.

Exceptional tip shape retention.
Reduces the relaxation and deformation seen with conventional wires after multiple passes through tortuous anatomy. Bench testing shows the tip holds its shape after simulated multiple vessel passes.
Enhanced torque transmission.
The polymer fill carries torque from the proximal core through the matrix to the tip. A cylindrical, tapered tip avoids restricted two-dimensional movement.
Less tip stiffness.*
The straight version has 46% less tip stiffness than conventional wires such as Synchro 14, for navigation in complex procedures.
A supportive mid-shaft.
Rail for 0.013 in tip microcatheter delivery at conventional wire levels, demonstrated in the distal 15 cm.
*Bench testing. May not be indicative of clinical performance.
"Prior to WaveSelect I likely would have used multiple competitive wires for this tortuous vessels case, but I only had to use a single WaveSelect due to its impressive shape retention."
Dr. Timo Krings, Lahey Hospital & Medical Center, MA

GW1410 at a glance.
| Specification | Value |
|---|---|
| Product code | GW1410 |
| Distal OD | 0.010 in |
| Proximal OD | 0.014 in |
| Total length | 200 cm |
| Radiopaque tip length | 3 cm |
| Coil length | 30 cm |
| Tip | Straight, shapeable |
| Coating | PTFE |
| Compatibility | 0.013 in tip microcatheters |
The lead for SurfRider 13.
WaveSelect 1014 guides SurfRider 13 into distal targets and facilitates delivery of embolic devices.
Indications for use
The WaveSelect Wire is intended for use in guiding microcatheters to the neurovasculature. WaveSelect facilitates the delivery of embolic devices for the endovascular treatment of brain aneurysms and other neurovascular conditions.
Important Safety InformationWaveSelect in U.S. labs.
Case results may not be indicative of results in other cases.
See WaveSelect 1014 in your own cases.
Your territory representative will set up product, in-service and case support for your lab.
Rx OnlyThank you. Your request is in.
Your Kaneka Neurovascular representative for your territory will reach out within one business day.