Read the wave.
Ride the line.
SurfRider 13 is a low-profile 0.013 in ID microcatheter with dual distal markers and DMSO compatibility. Designed to navigate. Built to deliver.
Rx Only
Built for the distal case.
Confirm position during coil delivery.
Two distal markers, 3 cm apart with a tip length of 0.8 mm or less. "The additional marker made it easier to confirm catheter position during i-ED coil deployment," said Dr. Alfred See of Boston Children's Hospital.

Low distal profile.
A 0.022 in (1.7F) distal OD with a 0.013 in ID, stepping to 2.8F proximally for support.
Braid + braid reinforcement.
Braided distal section, two-layer braid proximally, for trackability that holds position.
Coils and liquid embolics.
Compatible with Kaneka i-ED coils and DMSO-based liquid embolics. Onyx was delivered through SurfRider in a three-feeder AVF case.
Straight or pre-shaped.
"The pre-shaped configuration worked extremely well," said Dr. Shigematsu. "Even in a vessel with multiple turns, the catheter was delivered without difficulty."
SurfRider 13 at a glance.
| Specification | Value |
|---|---|
| Proximal OD | 0.037 in (2.8 Fr) |
| Proximal ID | 0.015 in |
| Distal OD | 0.022 in (1.7 Fr) |
| Distal ID | 0.013 in |
| Dead space | 0.27 ml |
| Flexible length | 25 cm |
| Coated length | 100 cm |
| Working length | 165 cm |
| Compatible guidewire max OD | 0.010 in |
| DMSO compatibility | Compatible |
| Marker band | Double |
| Distal reinforcement | Braid |
| Proximal reinforcement | Braid + braid (2 layer) |
Ordering
| Code | Description |
|---|---|
| N01-13165-ST | SurfRider 13 Microcatheter, straight tip |
| N01-13165-PS | SurfRider 13 Microcatheter, pre-shaped tip |
SurfRider 13 is indicated for delivery of 0.010 in coils and is compatible with the WaveSelect 1014 guidewire and other 0.010 in neurovascular guidewires.
Rides WaveSelect. Delivers the i-ED Coil.
Compatible with 0.010 in coils and the WaveSelect 1014 guidewire. The i-ED SilkySoft line fits through its 0.013 in lumen.
Indications for use
The SurfRider 13 Microcatheter is intended for the introduction of interventional devices, such as embolic coils, or diagnostic agents into the neurovasculature.
Important Safety InformationSurfRider 13 in U.S. labs.
Case results may not be indicative of results in other cases.
See SurfRider 13 in your own cases.
Your territory representative will set up product, in-service and case support for your lab.
Rx OnlyThank you. Your request is in.
Your Kaneka Neurovascular representative for your territory will reach out within one business day.